  trident connector system ringlock circular connectors r inglock is a range of robust circular connectors for industrial applications. it uses a metal bayonet coupling system for quick and reliable connections and thermoplastic bodies for low installed cost. the connectors are available in several sizes ranging from 4 to 48 circuits for signals of up to 13 a or coax. with the addition of a cable clamp, the connectors can be water sealed to meet ip65. applications: ? industrial electronics. ? robotic systems. ? manufacturing equipment. ? printing equipment. ? rugged metal coupling. ? available in unsealed and sealed versions. ? positive bayonet locking. ? shell to shell keying. ? integrally molded combined plastic body and insulator. ? wide range of accessories. ? accepts all trident signal and coaxial contacts. ? pcb versions are available. ? recognized under the component program of ul inc. and csa. performance specifications operating voltage 250 v ac rms contact current rating up to 13 a (for derating curve, see page 44) temperature range C55c to 105c (C67f to 221f) insulation resistance 5000 m? at 500 v dc materials and finishes product features dimensions are shown in mm (inch) dimensions subject to change www.ittcannon.com 18 ringlock circular description material finish insulator black nylon, ul 94v-0 none coupling ring high strength copper alloy nickel bayonet pins stainless steel bayonet pins support band high strength copper alloy nickel for more information: www.ittcannon.com/cat004
ringlock circular trident connector system ringlock circular connectors contact cavity arrangements mating face view, standard plug (mating face view, reversed plug is mirror image) * meets creepage and clearance requirements for vde 0110. note: the shell size indicates the diameter of the interface in sixteenths of an inch. example: shell size 16 is 1.00 inch in diameter, 25,4 mm. 19 dimensions are shown in mm (inch) dimensions subject to change www.ittcannon.com 19 way 7 way* 23 way shell size 16 shell size 18 shell size 18 28 way 35 way 48 way shell size 20 shell size 22 shell size 24 4 way 8 way 12 way shell size 10 shell size 12 shell size 14
trident connector system ringlock circular connectors important note: standard and reversed format equipment design dictates whether the fixed connector is live or dead when disconnected. connector housings are available that provide socket contacts on the live side of the equipment. standard format: receptacle with socket contacts. reversed format: receptacle with pin contacts. standard and reversed connectors are not intermateable. number of shell part number dimensions accessory contacts size (each) nomenclature a 0,20 (.008) b max. c 0,15 (.005) d 0,15 (.005) e thread 4 10 192922-1250 tr 1004 pms 1nb 21,60 (.850) 31,80 (1.252) 10,90 (.429) 12,20 (.480) 19,10 0,20 (.751 .007) 9 / 16 - 24 unef 7 18 192990-1330 tr 1807 pms 1nbe 34,30 (1.350) 33,00 (1.299) 22,50 (.885) 24,00 (.944) 19,10 0,20 (.751 .007) 1 1 / 16 - 18 unef 8 12 192922-1260 tr 1208 pms 1nb 24,80 (.976) 31,80 (1.252) 13,80 (.543) 15,10 (.594) 19,10 0,20 (.751 .007) 11 / 16 - 24 unef 12 14 192922-1270 tr 1412 pms 1nb 28,00 (1.102) 31,80 (1.252) 17,00 (.669) 18,30 (.720) 19,10 0,20 (.751 .007) 13 / 16 - 20 unef 19 16 192922-1280 tr 1619 pms 1nb 31,20 (1.228) 31,80 (1.252) 19,90 (.783) 21,40 (.842) 19,10 0,20 (.751 .007) 15 / 16 - 18 unef 23 18 192990-1320 tr 1823 pms 1nb 34,30 (1.350) 31,80 (1.252) 22,40 (.881) 24,00 (.944) 19,10 0,20 (.751 .007) 1 1 / 16 - 18 unef 28 20 192922-1290 tr 2028 pms 1nb 37,50 (1.476) 31,80 (1.252) 25,60 (1.007) 27,10 (1.066) 19,10 0,20 (.751 .007) 1 3 / 16 - 20 unef 35 22 192922-1300 tr 2235 pms 1nb 40,70 (1.602) 31,80 (1.252) 28,50 (1.122) 30,40 (1.196) 19,10 0,20 (.751 .007) 1 5 / 16 - 18 unef 48 24 192990-1340 tr 2448 pms 1nb 43,90 (1.728) 31,80 (1.252) 31,70 (1.248) 33,50 (1.318) 14,72 0,15 (.580 .006) 1 7 / 16 - 18 unef standard plug pin contacts dimensions are shown in mm (inch) dimensions subject to change www.ittcannon.com 20 ringlock circular ? mates with standard receptacles, see page 21. ? accepts pin contacts, see page 45. ? discriminating (keying) pins available, see page 50. ? can be water sealed to ip65.
trident connector system ringlock circular connectors ? mates with standard plugs, see page 20 ? accepts socket contacts, see page 45. ? printed circuit and coaxial contacts are available, see page 45. part numbers number shell unsealed of contacts size part number (each) nomenclature 4 10 192922-1190 tr 1004 rfs 1nb 7 18 192990-1300 tr 1807 rfs 1nbe 8 12 192922-1200 tr 1208 rfs 1nb 12 14 192922-1210 tr 1412 rfs 1nb 19 16 192922-1220 tr 1619 rfs 1nb 23 18 192990-1290 tr 1823 rfs 1nb 28 20 192922-1230 tr 2028 rfs 1nb 35 22 192922-1240 tr 2235 rfs 1nb 48 24 192990-1310 tr 2448 rfs 1nb number of shell a b c de f g h j accessory contacts size max. 0,15 (.005) 0,20 (.007) 0,15 (.005) 0,15 (.005) 0,25 (.009) 0,10 (.003) 0,10 (.003) 0,10 (.003) thread 4 10 25,80 (1.016) 2,30 (.091) 11,15 (.439) 15,00 (.591) 18,00 (.709) 23,50 (.925) 3,25 (.128) 17,30 (.681) 15,10 (.594) 9 / 16 - 24 unef 7 18 32,50 (1.280) 2,50 (.098) 18,20 (.716) 28,50 (1.122) 27,00 (1.063) 33,30 (1.311) 3,25 (.128) 31,30 (1.232) 27,80 (1.094) 1 1 / 16 - 18 unef 8 12 25,80 (1.016) 2,30 (.091) 11,35 (.447) 19,00 (.748) 20,50 (.807) 26,20 (1.031) 3,25 (.128) 21,80 (.858) 18,20 (.716) 11 / 16 - 24 unef 12 14 25,80 (1.016) 2,30 (.091) 11,35 (.447) 22,20 (.874) 22,60 (.890) 28,15 (1.108) 3,25 (.128) 25,00 (.984) 21,40 (.842) 13 / 16 - 20 unef 19 16 25,80 (1.016) 2,30 (.091) 11,35 (.447) 25,40 (1.000) 24,20 (.953) 30,50 (1.200) 3,25 (.128) 28,10 (1.106) 24,60 (.968) 15 / 16 - 20 unef 23 18 25,80 (1.016) 2,50 (.098) 11,35 (.447) 28,50 (1.122) 26,90 (1.059) 33,30 (1.311) 3,25 (.128) 31,30 (1.232) 27,80 (1.094) 1 1 / 16 - 18 unef 28 20 33,30 (1.311) 2,50 (.098) 14,50 (.571) 31,70 (1.248) 29,20 (1.150) 36,50 (1.437) 3,25 (.128) 34,50 (1.358) 30,90 (1.216) 1 3 / 16 - 18 unef 35 22 33,30 (1.311) 3,50 (.138) 14,50 (.571) 34,90 (1.374) 31,60 (1.244) 39,70 (1.563) 3,25 (.128) 37,70 (1.484) 34,10 (1.342) 1 5 / 16 - 18 unef 48 24 33,30 (1.311) 3,50 (.138) 15,30 (.602) 38,05 (1.498) 34,45 (1.356) 42,90 (1.689) 3,90 (.154) 40,90 (1.610) 37,30 (1.468) 1 7 / 16 - 18 unef standard receptacle socket contacts 21 dimensions are shown in mm (inch) dimensions subject to change www.ittcannon.com ringlock circular panel cutout j = flange in front of panel h = flange at rear of panel dimensions sealed (see important note below) part number (each) nomenclature 192990-1660 tr 1004 rfh 1nb 192990-1700 tr 1807 rfh 1nbe 192990-1670 tr 1208 rfh 1nb 192990-1680 tr 1412 rfh 1nb 192990-1690 tr 1619 rfh 1nb 192990-1710 tr 1823 rfh 1nb 192990-1720 tr 2028 rfh 1nb 192990-1730 tr 2235 rfh 1nb 192990-1740 tr 2448 rfh 1nb important note: sealed connectors a sealed receptacle has an o-ring seal that blocks moisture when the plug and receptacle are mated. however, the receptacle is not sealed in an unmated condition. for protection, dust caps are recommended for unmated receptacles, see page 24. plug connectors using a sealed cable clamp (see page 25) with jacketed cable will meet ip65 when mated to a sealed receptacle.
trident connector system ringlock circular connectors number of shell part number dimensions accessory contacts size (each) nomenclature a 0,20(.008) b max. c 0,15(.005) d 0,15(.005) e thread 4 10 192926-0500 tr 1004 pfs 1nb 21,60 (.850) 26,10 (1.027) 11,00 (.433) 12,20 (.480) 19,10 0,20 (.751 .007) 9 / 16 - 24 unef 7 18 192990-1390 tr 1807 pfs 1nbe 34,30 (1.350) 31,50 (1.240) 22,50 (.885) 24,00 (.944) 19,10 0,20 (.751 .007) 1 1 / 16 - 18 unef 8 12 192926-0510 tr 1208 pfs 1nb 24,80 (.976) 25,60 (1.008) 13,90 (.547) 15,10 (.594) 19,10 0,20 (.751 .007) 11 / 16 - 24 unef 12 14 192926-0520 tr 1412 pfs 1nb 28,00 (1.102) 26,80 (1.055) 17,10 (.673) 18,30 (.720) 19,10 0,20 (.751 .007) 13 / 16 - 20 unef 19 16 192926-0530 tr 1619 pfs 1nb 31,20 (1.228) 27,60 (1.087) 20,00 (.787) 21,40 (.842) 19,10 0,20 (.751 .007) 15 / 16 - 18 unef 23 18 192990-1380 tr 1823 pfs 1nb 34,30 (1.350) 25,60 (1.008) 22,50 (.885) 24,00 (.944) 19,10 0,20 (.751 .007) 1 1 / 16 - 18 unef 28 20 192926-0540 tr 2028 pfs 1nb 37,50 (1.476) 31,30 (1.232) 25,70 (1.011) 27,10 (1.066) 19,10 0,20 (.751 .007) 1 3 / 16 - 20 unef 35 22 192926-0550 tr 2235 pfs 1nb 40,70 (1.602) 31,30 (1.232) 28,60 (1.126) 30,40 (1.196) 19,10 0,20 (.751 .007) 1 5 / 16 - 18 unef 48 24 192990-1400 tr 2448 pfs 1nb 43,90 (1.728) 31,30 (1.232) 31,80 (1.252) 33,50 (1.318) 14,72 0,15 (.580 .006) 1 7 / 16 - 18 unef reversed plug socket contacts dimensions are shown in mm (inch) dimensions subject to change www.ittcannon.com 22 ringlock circular important note: standard and reversed format equipment design dictates whether the fixed connector is live or dead when disconnected. connector housings are available that provide socket contacts on the live side of the equipment. standard format: receptacle with socket contacts. reversed format: receptacle with pin contacts. standard and reversed connectors are not intermateable. ? mates with reversed receptacles, see page 23. ? accepts socket contacts, see page 45. ? discriminating (keying) pins available, see page 50. ? can be water sealed to ip65.
trident connector system ringlock circular connectors number shell unsealed of contacts size part number (each) nomenclature 4 10 192926-0440 tr 1004 rms 1nb 7 18 192990-1360 tr 1807 rms 1nbe 8 12 192926-0450 tr 1208 rms 1nb 12 14 192926-0460 tr 1412 rms 1nb 19 16 192926-0470 tr 1619 rms 1nb 23 18 192990-1350 tr 1823 rms 1nb 28 20 192926-0480 tr 2028 rms 1nb 35 22 192926-0490 tr 2235 rms 1nb 48 24 192990-1370 tr 2448 rms 1nb sealed (see important note below) part number (each) nomenclature 192990-1760 tr 1004 rmh 1nb 192990-1800 tr 1807 rmh 1nbe 192990-1770 tr 1208 rmh 1nb 192990-1780 tr 1412 rmh 1nb 192990-1790 tr 1619 rmh 1nb 192990-1810 tr 1823 rmh 1nb 192990-1820 tr 2028 rmh 1nb 192990-1830 tr 2235 rmh 1nb number of shell a b c de f g h j accessory contacts size max. 0,15 (.005) 0,20 (.007) 0,15 (.005) 0,15 (.005) 0,25 (.009) 0,10 (.003) 0,10 (.003) 0,10 (.003) thread 4 10 31,50 (1.240) 2,30 (.091) 11,35 (.447) 15,00 (.591) 18,00 (.709) 23,50 (.925) 3,25 (.128) 17,30 (.681) 15,10 (.594) 9 / 16 - 24 unef 7 18 34,20 (1.346) 2,30 (.091) 17,80 (.700) 28,50 (1.122) 27,00 (1.063) 33,30 (1.311) 3,25 (.128) 31,30 (1.232) 27,80 (1.094) 1 1 / 16 - 18 unef 8 12 31,50 (1.240) 2,30 (.091) 11,35 (.447) 19,00 (.748) 20,50 (.807) 26,20 (1.031) 3,25 (.128) 21,80 (.858) 18,20 (.716) 11 / 16 - 24 unef 12 14 31,50 (1.240) 2,30 (.091) 11,35 (.447) 22,20 (.874) 22,60 (.890) 28,15 (1.108) 3,25 (.128) 25,00 (.984) 21,40 (.842) 13 / 16 - 20 unef 19 16 31,50 (1.240) 2,30 (.091) 11,35 (.447) 25,40 (1.000) 24,20 (.953) 30,50 (1.200) 3,25 (.128) 28,10 (1.106) 24,60 (.968) 15 / 16 - 20 unef 23 18 31,50 (1.240) 2,50 (.098) 11,35 (.447) 28,50 (1.122) 26,90 (1.059) 33,30 (1.311) 3,25 (.128) 31,30 (1.232) 27,80 (1.094) 1 1 / 16 - 18 unef 28 20 33,00 (1.299) 2,50 (.098) 14,55 (.573) 31,70 (1.248) 29,20 (1.150) 36,50 (1.437) 3,25 (.128) 34,50 (1.358) 30,90 (1.216) 1 3 / 16 - 18 unef 35 22 33,00 (1.299) 3,50 (.138) 14,55 (.573) 34,90 (1.374) 31,60 (1.244) 39,70 (1.563) 3,25 (.128) 37,70 (1.484) 34,10 (1.342) 1 5 / 16 - 18 unef 48 24 34,80 (1.370) 3,50 (.138) 15,35 (.604) 38,05 (1.498) 34,45 (1.356) 42,90 (1.689) 3,90 (.154) 40,90 (1.610) 37,30 (1.468) 1 7 / 16 - 18 unef reversed receptacle pin contacts 23 dimensions are shown in mm (inch) dimensions subject to change www.ittcannon.com ringlock circular 23 dimensions are shown in mm (inch) dimensions subject to change www.ittcannon.com 23 ringlock circular ? mates with reversed plugs, see page 22. ? accepts pin contacts, see page 45. ? printed circuit and coaxial contacts are available, see page 45. dimensions 192990-1840 tr 2448 rmh 1nb part numbers panel cutout j = flange in front of panel h = flange at rear of panel important note: sealed connectors a sealed receptacle has an o-ring seal that blocks moisture when the plug and receptacle are mated. however, the receptacle is not sealed in an unmated condition. for protection, dust caps are recommended for unmated receptacles, see page 24. plug connectors using a sealed cable clamp (see page 25) with jacketed cable will meet ip65 when mated to a sealed receptacle.
panel gaskets for ringlock receptacle connectors trident connector system ringlock circular connectors part number dimensions shell size (each) nomenclature a max. b max. c max. h thread 10 192990-1430 tr 10 aad 21,00 (.827) 18,10 (.712) 19,20 (.755) 9 / 16 - 24 unef-2b 12 192990-1440 tr 12 aad 24,00 (.944) 23,40 (.921) 19,20 (.755) 11 / 16 - 24 unef-2b 14 192990-1450 tr 14 aad 27,00 (1.063) 24,20 (.952) 19,20 (.755) 13 / 16 - 20 unef-2b 16 192990-1460 tr 16 aad 30,20 (1.189) 29,60 (1.165) 21,50 (.846) 15 / 16 - 20 unef-2b 18 192990-1470 tr 18 aad 33,30 (1.311) 31,70 (1.248) 21,50 (.846) 1 1 / 16 - 18 unef-2b 20 192990-1480 tr 20 aad 36,50 (1.437) 35,80 (1.409) 22,80 (.897) 1 3 / 16 - 18 unef-2b 22 192990-1490 tr 22 aad 39,70 (1.563) 38,20 (1.503) 22,80 (.897) 1 5 / 16 - 18 unef-2b 24 192990-1500 tr 24 aad 42,90 (1.689) 41,30 (1.626) 21,90 (.862) 1 7 / 16 - 18 unef-2b shell part number part number dimension size (each) (pack of 100) a max. 10 192900-0666 192900-0676 21,80 (.858) 12 192900-0667 192900-0677 25,40 (1.000) 14 192900-0668 192900-0678 28,60 (1.126) 16 192900-0669 192900-0679 31,70 (1.248) 18 192900-0670 192900-0680 34,90 (1.374) 20 192900-0671 192900-0681 38,10 (1.500) 22 192900-0672 192900-0682 41,20 (1.622) 24 192900-0673 192900-0683 44,40 (1.748) adapters for heat shrink boots or sleeving plastic dust caps for receptacles dimensions are shown in mm (inch) dimensions subject to change www.ittcannon.com 24 ringlock circular ? protects unmated receptacles. ? durable construction for long-term use. ? for use with ringlock receptacles. shell size part number (pack of 100) 10 075-8543-011 12 075-8543-012 14 192900-0565 16 192900-0566 18 075-8543-015 20 192991-0566 22 075-8543-017 24 192900-0567 ? all panel gaskets are 1,50 (.059) thick.
trident connector system ringlock circular connectors part number dimensions shell size (each) nomenclature a max. b 0,15 (.005) c max. d 0,15 (.005) e* max. 10 192922-1310 tr 10 asr 1n 21,50 (.846) 6,40 (.251) 8,70 (.342) 21,00 (.826) 61,30 (2.413) 12 192922-1320 tr 12 asr 1n 24,90 (.980) 6,40 (.251) 12,80 (.503) 24,00 (.944) 61,30 (2.413) 14 192922-1330 tr 14 asr 1n 27,00 (1.063) 6,40 (.251) 13,80 (.543) 27,00 (1.063) 67,10 (2.641) 16 192922-1340 tr 16 asr 1n 30,10 (1.185) 6,40 (.251) 17,00 (.669) 30,20 (1.189) 67,10 (2.641) 18 192990-1510 tr 18 asr 1n 32,00 (1.259) 7,00 (.275) 19,90 (.783) 33,20 (1.307) 70,80 (2.787) 20 192922-1350 tr 20 asr 1n 34,30 (1.350) 7,00 (.275) 21,00 (.827) 36,40 (1.433) 79,30 (3.122) 22 192922-1360 tr 22 asr 1n 37,10 (1.460) 8,20 (.322) 23,00 (.905) 39,60 (1.559) 85,30 (3.358) 24 192990-1520 tr 24 asr 1n 41,80 (1.645) 8,20 (.322) 27,00 (1.063) 42,80 (1.685) 90,80 (3.574) part number dimensions shell size (each) nomenclature a max. b 0,20 (.007) c* max. 10 192990-1530 tr 10 ahc 1n 11,10 (.437) 18,80 (.740) 76,50 (3.011) 12 192990-1540 tr 12 ahc 1n 13,60 (.535) 20,80 (.818) 77,80 (3.063) 14 192990-1550 tr 14 ahc 1n 14,60 (.574) 22,80 (.897) 85,50 (3.366) 16 192990-1560 tr 16 ahc 1n 16,60 (.653) 24,70 (.972) 89,80 (3.535) 18 192990-1570 tr 18 ahc 1n 16,60 (.653) 24,70 (.972) 93,00 (3.661) 20 192990-1580 tr 20 ahc 1n 22,10 (.870) 31,80 (1.252) 107,50 (4.232) 22 192990-1590 tr 22 ahc 1n 22,10 (.870) 31,80 (1.252) 114,50 (4.507) 24 192990-1600 tr 24 ahc 1n 29,60 (1.165) 41,80 (1.645) 128,50 (5.059) * assumes a uniformly cylindrical cable. variations in the diameter could effect sealing. sealed cable clamps for use with ringlock circular connectors 25 dimensions are shown in mm (inch) dimensions subject to change www.ittcannon.com ringlock circular * for disassembly, add 9,00 (.354) for shell sizes 10-16 & add 10,60 (.417) for shell sizes 18-24. ? for use with jacketed cables. ? provides strain relief and wire protection. ? can be water sealed to ip65. see notes on pages 21 and 23. ? for assembly instructions, see page 57. unsealed cable clamps for use with ringlock circular connectors ? provides strain relief and wire protection. ? for assembly instructions, see page 57. * for disassembly, add 9,00 (.354) for shell sizes 10-16 & add 10,60 (.417) for shell sizes 18-24.


▲Up To Search▲   

 
Price & Availability of 192990-1840

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X